      Flexible configuration for optional inbuilt transformer
      Compatible with multiple battery technologies including Lithium Ion batteries
      Common battery option for optimised selection of Battery for UPS in parallel or Independent configurations
      Wide input voltage from +20% to -40%
      Genset compliant with adaptive progressive progressive walk-in and rectifier delay start options
      3 Phase 3 wire rectifier fully compatible with existing infrastructure
      Parallel upto 8 units for capacity or redundancy
    • Reliability
      Operating temperature of 0-40oC with special attention in component selection and design to improve reliability
      Input phase sequence correction provided as standard
      Advanced battery management techniques to improve battery life with three stage charging and with auto equalizing charge at predefined intervals
      Monitoring runtime of critical component such as fans, capacitors, batteries for predictive life estimation
    • Total Cost of Ownership
      Efficiency of upto 96.5% in online double conversion mode
      Intelligent Eco mode operation with an efficiency of upto 99%
Model
UPS Rating (KVA) 100 120 160 200 250 300
UPS Rating (KW) 100 120 160 200 250 300
Input Parameters  
Rated Voltage 400 V, 3 Phase + PE
Rated Voltage Tolerance +20%, -40%*
Rated Frequency 50/60 Hz
Current Harmonic Distortion (THDi) ** < 3% at load 100%>
Bypass Parameters  
Rated Voltage 400 V ± 10%, 3 Phase + N + PE
Rated Frequency 50 or 60 Hz (Configurable)
Output Parameters  
Rated Voltage 400 V (Settable 380/415 V), 3 Phase + N + PE
Rated Frequency 50 or 60 Hz (Configurable)
Voltage Variation - Static load ±1%
Crest Factor 3:1
Voltage Distortion at Linear Load ≤1% (Typical)
Voltage Distortion at Non-Linear Load (as per IEC62040) ≤3%
Frequency Stability with Inverter Synchronized to The By-Pass Mains ±2% (Settable from ±1% to ±6%)
Voltage Phase Shift with Balanced and UnBalanced Load 120 ± 1°
Overload Capacity at 40°C 110% for 60 mins, 125% for 10mins, 150% for 1min
Load Power Factor 0.7 Leading to 0.5 Lagging without Derating
Efficiency Upto 99% in Eco Mode and upto 95.5% in Online Mode
Battery Parameters  
Nominal Battery Voltage 480 Vdc
Compatibility Compatible with SMF, Tubular, Ni-Cd, Li -Ion Battery
Environmental Parameters  
Ambient Temperature for the UPS 0 to 40°C
Range of Relative Humidity upto 95% max (without Condesing)
Maximum Operating Altitude Up to 1000 above MSL
Storage Temperature From -25°C up to 60°C (UPS))
Acoutic Noise at 1m from Panel Front (Ref ISO3746) < 65 dba
Mechanical Parameters  
Dimension(W*D*H in mm) 840*900*1800 1000*1000*2000 1200*1000*2050
Weight in Kgs(Approx) 400kgs 850kgs 900kgs

* at Part Load
**THDv @ <1%

ENQUIRY

CUSTOMER SUPPORT
078 1000 9955

ASK PROF. WATT

Looking for help to identify a solution for your home or business?

Ask Prof. Watt >

ASK PROF. WATT

NEWS

Fuji Electric announces India 2.0 plan – In India for India+
Nov 7, 2019

Fuji Electric signs Agreement to acquire Consul Neowatt
Jun 20, 2019

Consul Neowatt expands its operations to Bangladesh
Jun 19, 2019

In Focus Interview
Aug 1, 2018 | Engineering Review

Read more >
 

MOBILE APP

MOBILE APP

The Fuji Electric Consul Neowatt Warranty and Service app puts the warranty / service information of your Fuji Electric Consul Neowatt product in the palm of your hand.

CLICK HERE

Client Speak