Products

Finch PW

Finch PW is specifically designed for operation in poor power quality areas. Finch PW provides high power density with long backup time in compact size. It's ideal for ATMs, banking and other business critical applications where a higher backup time is required. Finch PW provides the flexibility to adjust charging current from 1A to 6A according to different applications and the possibility to have an additional charger to support longer backup times. 

  • Features & Benefits

  • Technical Specifications

  • Documentation

      • Online double conversion UPS.
      • Input power factor corrector 0.99 (PFC)
      • Automatic bypass, allow to transfer the load to the mains in case of overload or internal fault
      • Configurable as Single Phase Input & Output or Three Phase Input and Single Phase output on 10KVA
      • Inbuilt Isolation Transformer (optional) provides a galvanic isolation between the mains and the loads
      • Hot standby Configuration to ensure the availability of Quality power to mission critical applications
      • Battery cold start feature allows UPS to be powered on from the battery without utility
      • Inbuilt Manual bypass in 6 & 10KVA to facilitate concurrent maintenance without disturbing the loads
      • Compact and reduced foot print with inbuilt battery on 1 - 6KVA
Model
Configuration Single Phase with Ground
Configuration 3-phase in / 3-phase out 3-phase in / 1-phase out
Capacity 1KVA 2KVA 3KVA 6KVA 10KVA
Capacity 800W 1.6KW 2.4KW 4.8KW 8KW
INPUT
Nominal Voltage 200/208/220/230/240VAC
Input Voltage Range 110-300V AC (at 50% Load) or
160-280V AC (at 100% Load)
110-300V AC (at 50% Load) or
176-300V AC (at 100% Load)
Frequency Range 40 Hz -70 Hz 46 Hz -54 Hz
Power Factor ≥ 0.99@ Nominall Voltage (100% load)
OUTPUT
Output Voltage 200/208/220/230/240VAC
Voltage Regulation ±1%
Frequency Range (Synchronized Range) 47 - 53 Hz 46 - 54 Hz
Frequency Range (Batt. Mode) 50 Hz ± 0.25 Hz 50 Hz ± 0.1 Hz
Current Crest Ratio 3:1
Harmonic Distortion ≤3% THO (Linear Load)
≤6% THO (Non-Linear Load)
≤3% THO (Linear Load)
≤5% THO (Non-Linear Load)
Waveform (Batt. Mode) Pure Sinewave
Overload 105%- 110%: 10mins; 110%- 130%- 1 min; >130%- 10 sec
EFFICIENCY
AC Mode 88% 88% 90% 92% 93%
BATTERY
Built in Battery Battery Type 12 V/9Ah 12 V/7Ah 12 V/7Ah 12 V/7Ah  
Numbers 2 8 8 16  
Typical Recharge Time 4 hours recover to 90% capacity 9 hours recover to 90% capacity
Charging Current (max.) 1A 1A / 2A
Long-run Model Battery Type Depending on the capacity of external batteries
Numbers 3 6 6 16 or 20
Charging Current (max.) 1A/2A/4A/6A (Adjustable) 1 A/2A/ 4A (Adjustable, 4A is only available)
Additional Charger 12A 12A 12A 4A 4A
INDICATORS
LCD Load Level, Battery level, AC mode, Battery mode, Bypass mode and Fault indicators
PHYSICAL
Standard Model Dimension, D x W x H(mm) 282 X 145 X 220 397 X 145 X 220 421 x 190 x 318 369 X 190 X 688  
Net Weight (kg) 9.8 17 27.6 61  
Long-run Model Dimension, D x W x H(mm) 282 X 145 X 220 397 X 145 X 220 369 X 190 x318 442 X 190 X 318
Net Weight (kg) 4.1 6.8 7.4 12 16
PHYSICAL
Humidity 20-90 % RH @ 0- 40"C (Non-condensing)
Noise Level Less than 58dB @ 1 Meter
MANAGEMENT
Smart RS-232 / USB Supports Windows®2000/2003/XP/Vista/2008, Windows®7/8, Linux and MAC
Optional RS485 SNM P, Modbus(RS485) and Potential Free Contact

All specifications are subject to change
Custom models available on request

ENQUIRY

CUSTOMER SUPPORT
078 1000 9955

ASK PROF. WATT

Looking for help to identify a solution for your home or business?

Ask Prof. Watt >

ASK PROF. WATT

NEWS

Fuji Electric announces India 2.0 plan – In India for India+
Nov 7, 2019

Fuji Electric signs Agreement to acquire Consul Neowatt
Jun 20, 2019

Consul Neowatt expands its operations to Bangladesh
Jun 19, 2019

In Focus Interview
Aug 1, 2018 | Engineering Review

Read more >
 

MOBILE APP

MOBILE APP

The Fuji Electric Consul Neowatt Warranty and Service app puts the warranty / service information of your Fuji Electric Consul Neowatt product in the palm of your hand.

CLICK HERE

Client Speak