Products

Finch PG

Finch PG is a double-conversion online UPS with a output power factor 0.9 providing higher power density, delivering 12.5% more power when compared with conventional UPS (designed with output power factor of 0.8). Finch PG is with DSP technology and active input power factor correction design to ensure better output voltage conditions, power quality and power performance at all times. Its dual mains inputs will secure the power reliability in areas with poor power quality. 

  • Features & Benefits

  • Technical Specifications

  • Documentation

      • Online double conversion UPS
      • Input power factor corrector 0.99 (PFC)
      • Automatic bypass, allow to transfer the load to the mains in case of overload or internal fault
      • Output Power factor of 0.9
      • Configurable as Single Phase Input & Output or Three Phase Input and Single Phase output on 10KVA
      • Hot standby configuration to ensure the availability of quality power to mission critical applications
      • Battery cold start feature allows UPS to be powered on from the battery without utility
      • Can be paralleled upto 3 units for capacity and/or redundancy
      • Flexible/settable battery configuration
 
MODEL Finch PG
Configuration 3-phase in / 3-phase out 3-phase in / 1-phase out
Capacity l0KVA 20KVA 30KVA l0KVA 20KVA
Capacity 9KW 18KW 27KW 9KW 18KW
INPUT
Nominal Voltage 3 x 400 VAC (3Ph+N)
Input Voltage Range 190-520 VAC (3-phase) at 50% load
305-478 VAC (3-phase) at 100% load
Frequency Range 46~54 Hz or 56~64Hz
Power Factor ≥ 0.99 @ 100% Load
OUTPUT
Output Voltage 3 x 400 VAC (3Ph+N) 220/230/240VAC (1Ph+N)
AC Voltage Regulation ±1%
Frequency Range 46~54Hz
Frequency Range (Batt. Mode) 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz
Current Crest Ratio 3:1 (max.)
Harmonic Distortion ≤2% THD (Linear Load)
≤5% THD (Non-linear Load)
Transfer Time Zero
Waveform (Batt. Mode) Pure Sinewave
Overload 105% - 110% : 10mins; 110% - 130% - 1 min; >130% - 3 sec
EFFICIENCY
AC Mode 90.5% 91.5% 92.1% 91.50% 91.50%
ECO Mode 96% 97%
BATTERY
Battery Type SMF VRLA/Vented Battery
Numbers 20 Nos (18 - 20 adjustable)
Typical Recharge Time 9 hours recover to 90% capacity
Charging Current (max.) 4A 4A 12A 4A 4A
INDICATORS
LCD Display UPS status, Load level, Battery level, Input/Output voltage, Discharge timer and Fault
PHYSICAL
Dimension,
xW xH (mm)
592 X 250 X 826 592 X 250 X 826 815 X 250 X 826 592 X 250 X 826 592 X 250 X 826
Net Weight (kg) 38 40 64 28 40
Humidity 0-95 % RH @ 0- 40°C (Non-condensing)
Noise Level Less than 60dB @ 1 Meter
MANAGEMENT
Smart RS-232 / USB Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8, Linux and MAC
Optional RS485 SNMP, Modbus(RS485) and Potential Free Contact

All specifications are subject to change
Custom models available on request

ENQUIRY

CUSTOMER SUPPORT
078 1000 9955

ASK PROF. WATT

Looking for help to identify a solution for your home or business?

Ask Prof. Watt >

ASK PROF. WATT

NEWS

Fuji Electric announces India 2.0 plan – In India for India+
Nov 7, 2019

Fuji Electric signs Agreement to acquire Consul Neowatt
Jun 20, 2019

Consul Neowatt expands its operations to Bangladesh
Jun 19, 2019

In Focus Interview
Aug 1, 2018 | Engineering Review

Read more >
 

MOBILE APP

MOBILE APP

The Fuji Electric Consul Neowatt Warranty and Service app puts the warranty / service information of your Fuji Electric Consul Neowatt product in the palm of your hand.

CLICK HERE

Client Speak